Описание оборудования | |
|---|---|
| AS-Interface EMERGENCY STOP button | |
General specifications | |
| Slave type | Safety-Slave |
| AS-Interface specification | V2.1 |
| Required master specification | ? V2.0 |
| UL File Number | E198304 |
Functional safety related parameters | |
| MTTFd | 200 a |
| B10d | 1 E+5 |
Electrical specifications | |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ? 40 mA |
| Protection class | III |
| Insulation resistance | min. 100 M? |
Input | |
| Number/Type | 2 NC Safety function by positive opening in accordance with IEC/EN 60947-5-1 Reset by pulling |
| Supply | from AS-Interface |
Output | |
| Number/Type | LED red |
| Supply | from AS-Interface |
Directive conformity | |
| Electromagnetic compatibility | |
Standard conformity | |
| Electromagnetic compatibility | EN62026-2:2013 |
| Degree of protection | EN60529:2000 |
| Electrical safety | EN60947-5-5:1997+A1:2005 |
| AS-Interface | EN62026-2:2013 |
| Functional safety | EN62061:2005 EN61508 Parts 1-7:2010 NFPA 79:2007 EN60204-1:2006 |
Programming instructions | |
| Profile | S-7.B.E. |
| IO code | 7 |
| ID code | B |
| ID1 code | F |
| ID2 code | E |
| Data bits (function via AS-Interface) | input output |
| Parameter bits (programmable via AS-i) | function |
Ambient conditions | |
| Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) (no freezing) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Relative humidity | 40 ... 85 % , noncondensing |
Mechanical specifications | |
| Operating force | Push: 32 N Pull: 21 N Turn: 0.27 Nm Minimum for positive opening operation: 60 Nm |
| Operating distance | for positive opening operation: min. 4 mm maximal: 4.5 mm |
| Degree of protection | IP65 |
| Connection | Crimp terminal sockets (JST) 1.5m Connecting cable with crimp on 2 flexible leads supplied with delivery |
| Installation | Installation in 22 mm hole |
| Mass | 105 g |
| Life span | > 250,000 switching operations |
8 (029) 555-8-000 | |